Product Information
The TPI 9080-EX is a simple, easy to use, Intrinsically Safe vibration meter that records, analyzes and displays vibration signals at the push of a button. Identify the vibration problem: unbalance, misalignment or looseness; in addition to the bearing condition. VibTrend PRO software gives you greater ease of use and flexibility. Windows 10™ compatible.
- Store analyze and report on all your vibration parameters in one place; up to 10 assets with 10 readings per asset standard; unlimited assets with 10 readings per asset with included A9084 VibTrend Pro software.
- All information is just a click away. Color coded alarms highlight problems. Trend lines show problems before they happen.
Overall machine and bearing conditions: vibration values are displayed with color coded alarm levels for ISO values and Bearing Damage (BOU).
Identify complex issues: 800-line spectrum with zoom and cursor.

Identify complex issues: 800-line spectrum with zoom and cursor.
Identify the vibration problem: unbalance, misalignment or looseness in addition to the bearing condition.
- Find machine faults before they stop your machine
- Increase productivity and lower maintenance costs
The Smart Trend Meter 9080 allows easy display of vibration signals . The meter automatically performs vibration analysis functions based on machine running speed to help diagnose faults such as unbalance, misalignment and looseness.
 | Features
- Intrinsically Safe. IEC Ex/ATEX Ex ib IIC T4 Gb
(-20°C < Ta < +40°C)
Certificate Numbers: IECEx BAS 16. 0131X Baseefa 16ATEX0182X
- Collect data
- Trend data using VibTrend PRO software
- EX accelerometer with cable and magnet
- Built-in Bluetooth communication capability
- USB docking station to download to a PC
- Built-in ISO Vibration Alarms
- Easily identify bearing problems with BDU Reading
- Easily identify problems with built-in band filters: 1X (unbalance) 2X (misalignment) 3X (looseness)
- 800 line FFT (spectrum)
- Ruggedized IP67 case
- 3-year Limited Warranty
|
The system is designed to enable a user to take vibration measurements from assets (e.g. pumps, motors, fans and bearings) . The unit displays vibration frequency plots and allows vibration severity and bearing condition to be monitored.
Applications include:
- Commercial & Industrlal HVAC
- Food Processing
- Manufacturing
- Mining
- Packaging
- Petrochemical
- Pulp and Paper
- Power Plants
- Utilities
- Automotive
Specifications
Size |
200 mm x 60mm x 26mm |
Weight |
280g (not including magnet) |
Environmental |
|
Water, Sand & Dust |
IP67 Waterproof |
Operating |
0°C to 50°C |
Storage |
-20°c to 70°C |
Power supply |
2 x AA batteries |
Battery life |
Auto power OFF - typically 20 hours continuous operating time depending on brightness setting. |
Frequency range |
2 Hz to 1kHz (ISO) 1 kHz to 10 kHz (BOU) |
Max frequency resolution |
1.25 Hz @ 800 lines FFT setting
Acceleration in g
Velocity in mm/s (or inch/s)
Bearing noise in BOU (bearing damage units)
Displacement (mm, microns, inch) |
Displayed Frequency Units |
Hertz (Hz), RPM or CPM |
Input range |
User selectable with accelerometer sensitivity |
Dynamic range |
96 dB (0.01g resolution) |
VA diagnostic bands (RPM = run speed) |
Unbalance 1x RPM
Alignment 2x RPM
Looseness 3x RPM |
Note: The 9080-Ex can be used with non-intrinsically safe accessories in non hazardous areas. Only the 9080-Ex and A9093 intrinsically safe accelerometer should be taken into hazardous areas.

|
|
 |
 |
 |
 |

|