| 0.05% accuracy*, 50,000 count display, CAT IV 600volts, True RMS DMM.
AC/DC volts, AC/DC amps, resistance, audible continuity, diode test, frequency, capacitance, and temperature Plus: db,inductance, conductance, duty cycle, pulse width and time stamp logging.
The Triple Display 194 is an innovative new concept in DMM design. The unique display enables you to view more than one event at a time. This eliminates the hassle of switching back and forth to review minimum, maximum or preset comparative values. The meter is also easy to use and built to last.
The DMM 194 is a hand-held autoranging DMM. The backlit LCD can display three readings at one time. In addition to basic function of AC/DC V, AC/DC A, Ohm, Diode test, continuity, Capacitance, Frequency, there is the adaptor function. The meter also has RS232 output and software for recording information into a PC. |
Features
- Large 50,000 count display increases resolution and improves accuracy (1.7" x 2.75", 43mm x 70mm
- Triple Display shows more than one reading simultaneously
- 51 Segment Analog Bar Graph to catch fast AC fluctuations
- Back Light (LED Type) allows viewing in any light condition
- Auto Range automatically selects the best range for the measurement
- Separate battery and fuse compartment for easy replacement
- True RMS needed to accurately measure nonsinusoidal AC voltage and current waveforms found on controls and circuits
- Increased safety with Silicone rubber 1,000V CAT III, 600V CAT IV, 10A test leads (CE & cUL listed)
- Auto Power Off DMM will automatically power down after approximately 15 minutes of inactivity to extend battery life. Disable Auto Power Off: Hold down the REC button and turn the meter on.
- Diode Test displays approximate forward bias voltage
- Continuity and buzzer to check for opens and shorts
|
TPI 194 Specifications
DC Volts |
Maximum Input: 1000V
Maximum Resolution: 0.0001mV
Accuracy: ±0.05% |
AC Volts |
Maximum Input: 1000V
Maximum Resolution: 100ììV
Accuracy: ±0.4% |
DC Amps |
Maximum Input: 10A
Maximum Resolution: 0.01ìA
Accuracy: ±0.15% |
AC Amps |
Maximum Input: 10A
Maximum Resolution: 0.01ìA
Accuracy: ±0.75% |
Resistance (Ohms) |
Maximum Input: 50MÙ
Maximum Resolution: 1mÙ
Accuracy: ±0.05% |
Frequency |
Maximum Input: 5MHz
Maximum Resolution: 0.001Hz
Accuracy: ±0.05% |
Capacitance |
Maximum Input: 20mF
Maximum Resolution: 0.01nF
Accuracy: ±2% |
Inductance |
Maximum Input: 300mH
Maximum Resolution: 0.01mH
Accuracy: ±5% |
Temperature
(K-Type Thermocouple) |
Maximum Input: -54 to 2462°F (-50 to 1350°C)
Maximum Resolution: 0.1°F/°C
Accuracy: ±2% |
Continuity |
Audible at less than 10Ù |
Diode |
3V at 1mA maximum output |
Duty Cycle |
Maximum Input: 99.9%
Maximum Resolution: 0.1% |
True RMS Responding |
Yes |
Conductance |
Yes |
Pulse Width |
Yes |
Data Hold |
Yes (Two hold system) |
Min/Max Record |
Yes |
Time Stamp Logging |
Yes |
Relative Mode |
Yes |
Compare Mode |
Yes |
RS-232 Output |
Yes, Optically Isolated |
Process Loop Output |
No |
Sleep Mode / Auto Off |
Yes |
Protective Boot |
Yes (standard) |
Display Type |
50,000 count backlit LCD with dual sub displays and analog bargraph |
Range Selection |
Auto/Manual |
Operating Temperature |
32 to 113°F (0 to 40°C) |
Storage Temperature |
-4 to 140°F (-20 to 60°C) |
Humidity |
80% non-condensing |
Size |
8.3" x 3.7" x 1.9" (210mm x 95mm x 47mm) without boot
8.7" x 4.3" x 2.6 (220mm x 110mm x 65mm) with boot |
Weight |
1.3lbs (570g) without boot
1.9lbs (850g) with boot |
Battery Type |
9V Alkaline (NEDA 1604) |
Battery Life |
50hrs Typical |
OverInput Category |
CAT IV 600V |
Agency Approval |
cULus 61010-1, IEC 61010-1 |
Warranty |
Limited Lifetime |
|
|
|