The TI-25DL Wall Thickness Gauge accurately measures wall thickness and the extent of corrosion of all metals, ceramics, glass and most rigid plastics - from only one side!
The gauge can be used in a Single Thickness Reading mode or in two alternative modes, the Scan mode and the and the Differential mode. The Scan modes permits the user to "drag" the probe over a large measuring area where the minimum thickness encountered during the scan will be displayed. The Differential mode displays the difference ("+" or "-") from a set "nominal" value
The TI-25DL incorporates a built-in memory for 1000 data points that can be separated into 10 separate "batches." The stored data can be downloaded to a serial printer or a personal computer. A Windows compatible data transfer program is supplied at no additional cost.
Features
-
Resolution of 0.001 inch (0.01 mm)
-
Large, backlit LCD display retains last reading
-
Simple operator controls virtually eliminate training
-
Special-purpose probes are offered for a variety of applications
-
Switch-selected units for inches or mm
-
Memory for 1000 data points in up to 10 batches
-
Windows compatible data transfer program supplied at no additional cost.
-
CE Certified
-
NIST Calibration Certificate
The TI-25DL is supplied as a complete kit with: /span>
-
Gauge and Probe,
-
Data transfer software,
-
Serial output cable,
-
4 oz. bottle of coupling fluid,
-
2 AA batteries,
-
NIST Calibration Certificate and Operating Instruction Manual
-
Foam-fitted carrying case.
-
Range in Steel: 0.025-6.00" (0.60-150.0 mm)
-
Resolution: .001" (0.01 mm)
-
Display:
-
4½ - Digit,
-
0.5" Backlit LCD
-
Velocity Range: 6,500-33,000 ft./sec (2000-10,000 m/sec.)
-
Probe:
-
7.5 MHz,
-
0.25" Diameter (6.35 mm)
-
Cable:
-
4 ft. (1.2 m) waterproof cable with non-polarized, quick-disconnect connectors.
-
Optional lengths up to 50 ft. (15 m).
-
Temp. Limits:
-
Ambient: -20 to 120° F (-30 to 50° C)
-
Material: -0 to 200° F (-20 to 100° C
-
Special high temperature probes are optionally available.
-
Battery Type: Two AA batteries
-
Battery Life: 200 hours
-
Weight: 7 ounces (196 g)
-
Size: 2.5 x 4.5 x 1.25" (64 x 114 x 32 mm)
-
Accessories: Included
-
Probe/cable assembly.
-
4 oz. bottle of coupling fluid,
-
NIST Calibration Certificate,
-
2 AA batteries,
-
operating instructions,
-
hard-plastic carrying case.
-
Warranty
-
Gauge: 5 Years
-
Probes: 90 Days
Limits
Minimum Radius for Convex Surfaces: 0.350" (8.89 mm)
Minimum Radius for Concave Surfaces: 3" (76.2 mm)
Minimum Headroom for Probe: 1" (25.0 mm)
Minimum Sample Diameter: 0.150" (3.8 mm)
|
|
|