Features
- 1000A Clamp measures 1f or 3f (phase) power to 600KkW
- Display True Powe, Apparent Power, Power Factor, True RMS Voltage and Current, Resistance and Frequency
- Dual display of kW+PF, kVA+FP, V+A, A+Hz or V+Hz
- Clamp jaws open to 1.8" (46mm)
- Built-in recorder datalogs up to 4000 readings or download to a PC
- 25 point data memory viewable on the LCD display
- Full function display on large 4-digit LCD with fast 40 segmant bar graph, Peak Hold and MIN/MAX
- RS-232 module with PC software to capture and display data
- Complete with RS-232 module, Windows 95/98/NT/2000/ME/XP compatible software, cable, 9V battery, alligator clips, test leads, and carrying case
Specifications / Range / Resolution / Basic Accuracy
- True Power: 600KW / 10W / +/-(2%rdg+5d)
- Apparent Power: 1000KVA / 10VA / +/-(2%rdg+5d)
- Peak Current: 1000A / 0.1A / +/-(6%rdg+10d)
- Peak Voltage: 600V / 0.1V / +/-6%rdg+10d)
- AC Current (40-500Hz): 1000A / 0.1A / +/-)1.5%rdg+5d)
- AC Voltage: (40-500Hz): 600V / 100mV / +/-(0.5%rdg+5d)
- DC Voltage: 600V / 100mV / +/-(0.5%rdg+5d)
- Frequency : 500Hz / 0.1Hz / +/-(0.5%rdg+5d)
- Resistance: 10Kohm / 1ohm / +/-(1%rdg+5d)
- Continuity: Beeper when <50ohm
- Dimensions/Weight: 10.2x3.7x1.8" (260x93x45mm) / 15.9oz (450g)
Ordering Information
- 382065 : Clamp On Power Datalogger
- 382068 Clamp On Power Datalogger Kit with Software
- 382068-NISST : Clamp On Power Datalogger w/NIST Certificate
- 382062-1 : Plug in RS =-232 Interface Module with Software
- 480172 : 3 Prong AC Line Seperator
|
|
|
|
|
|
|